FAST-16 series portable real-time fluorescence quantitative PCR system can be equipped with a maximum of 3-6 fluorescence detection channels and a standard detection flux of 16 holes. It can complete all experimental operations and results analysis through the built-in touch screen. With small body design, optional external battery and other characteristics, small size, light weight, easy to carry, the system easily meets the needs of doing experiments outside. With powerful function, it can be used for relative quantitative, melting curve, positive and negative analysis. Built-in 7 "hd capacitive screen PDA, touch screen operation, simply and quickly. 16x0.2ml reaction module, compatible with eight-row tube and single tube. External battery is optional to meet the needs of doing experiments in the wild .It can fully meet the needs of small flux experiments and the experiments outside with simple and intuitive software guidance, and open fluorescence quantitative PCR experiment easily.
Specification
System Specs | Item | Specification |
General requirements | ||
Model | Fast-16-3,Fast-16-6 | |
Sample capacity | 16 samples | |
PCR tube | 200 uL tubes | |
Sample volume | 20-100uL | |
Dynamic range | 10 orders | |
Sensitivity | 1 copy | |
Supported Dyes | FAM,HEX,ROX,CY5,CY5.5,atto425 | |
Multiplexing | 3targets,6targets | |
Thermal cycling | ||
Temperature control range | 4-100℃ | |
Temperature accuracy | +/-0.2℃ | |
Temperature uniformity | <1.5℃ | |
Thermal | ||
Temperature uniformity | ≤ ±0.15°C @ 65°C | |
Maximum heating rate | ≥ 3.5°C/S | |
Average heating rate | ≥ 2.5°C/S | |
Maximum cooling rate | ≥ 3.5°C/S | |
Average cooling rate | ≥ 2.5°C/S | |
Temperature accuracy | ≤ ±0.1°C @ 65°C | |
Hot lid temperature | Ambient - 120°C | |
Fluorescence detection | Fluorescence channels | 3 channels (FAM,HEX,ROX), 6channels(FAM,HEX,ROX,CY5,CY5.5,atto425) |
Fluorescence detection sensitivity(umol) | 2-11 | |
Fluorescence intensity detection repeatability | CV<3% | |
fluorescence intensity detection precision | CV<5% | |
Different channel fluorescence interference | The fluorescence detection intensity of other channels is not higher than the fluorescence threshold of the target channel | |
Sample test repeatability | CV<3% | |
sample linearity | r≧0.98 | |
Fluorescence linearity | r≧0.99 | |
Scan Speed | Scan Speed | 7 sec/16sample |
Excitation | ||
1 | 470±10nm | |
2 | 535±10nm | |
3 | 575±10nm | |
4 | 628±10nm | |
5 | 682±10nm | |
6 | 430±10nm | |
Detection | ||
1 | 515±10nm | |
2 | 565±10nm | |
3 | 610±10nm | |
4 | 670±10nm | |
5 | 725±10nm | |
6 | 480±10nm | |
Light & detector | LEDs & Photodiodes | |
System Specs | ||
Dimension | 360*280*160mm | |
Weight | 6Kg | |
Power supply | 110V - 220V AC, 50-60Hz | |
Noise level | 45dB | |
Communications | USB | |
Operation Temperature | 15 - 30 °C | |
Operating Humidity | ≤ 85%, non-condensing | |
Approvals | CE |